Isolation transformers

Robust and generously dimensioned isolation transformers for powering all devices that need to be
separated from the power supply network. A wide range of devices solves the requirements for
separating various devices from the power grid in fields such as electrotechnical production,
development, research, education and hospitals.

Characteristics of isolating transformers

  • Sine waveform of the output voltage 50Hz (same as the mains).
  • Output voltage separated from the mains supply.
  • Soft-start function for power devices.
  • Robust metal chassis.
  • Sufficiently dimensioned transformer for permanent supply of power to the load.

OT230.012

230 V / 230 V / 1,2 A

OT230.021

230 V / 230 V / 2,1 A

OT230.030

230 V / 230 V / 3,0 A

OT230.050

230 V / 230 V / 5,0 A

OT230.100

230 V / 230 V / 10,0 A

OT230.200

230 V / 230 V / 20,0 A

OT230.012

230 V / 230 V / 1,2 A

Technical parameters

Power voltage 230 V / 50 Hz
Output voltage 230 V
Output current 1,2 A
Output frequency 50 Hz (identical to network frequency)
Output voltage stability by network stability
Stability of the output frequency by network stability
Galvanically separate output YES
Fuse input T 250 V / 1,25 A
Fuse Output T 250 V / 1,25 A
The length of the supply cord 2 m
Dimensions (V, W, H – approx.) 172 x 164 x 282 mm
Weight 6,0 kg
Warranty 24 months

OT230.021

230 V / 230 V / 2,1 A

Technical parameters

Power voltage 230 V / 50 Hz
Output voltage 230 V
Output current 2,1 A
Output frequency 50 Hz (identical to network frequency)
Output voltage stability by network stability
Stability of the output frequency by network stability
Galvanically separate output YES
Fuse input T 250 V / 3,15 A
Fuse Output T 250 V / 2,5 A
The length of the supply cord 2 m
Dimensions (V, W, H – approx.) 172 x 164 x 282 mm
Weight 6,3 kg
Warranty 24 months

OT230.030

230 V / 230 V / 3,0 A

Technical parameters

Power voltage 230 V / 50 Hz
Output voltage 230 V
Output current 3 A
Output frequency 50 Hz (identical to network frequency)
Output voltage stability by network stability
Stability of the output frequency by network stability
Galvanically separate output YES
Fuse input T 250 V / 4,0 A
Fuse Output T 250 V / 3,15 A
The length of the supply cord 2 m
Dimensions (V, W, H – approx.) 172 x 164 x 282 mm
Weight 15,4 kg
Warranty 24 months

OT230.050

230 V / 230 V / 5,0 A

Technical parameters

Power voltage 230 V / 50 Hz
Output voltage 230 V
Output current 5,0 A
Output frequency 50 Hz (identical to network frequency)
Output voltage stability by network stability
Stability of the output frequency by network stability
Galvanically separate output YES
Fuse input T 250 V / 6,3 A
Fuse Output T 250 V / 6,3 A
The length of the supply cord 2 m
Dimensions (V, W, H – approx.) 172 x 244 x 282 mm
Weight 16,7 kg
Warranty 24 months

OT230.100

230 V / 230 V / 10,0 A

Technical parameters

Power voltage 230 V / 50 Hz
Output voltage 230 V
Output current 10,0 A
Output frequency 50 Hz (identical to network frequency)
Output voltage stability by network stability
Stability of the output frequency by network stability
Galvanically separate output YES
Fuse input T 250 V / 12,5 A
Fuse Output F 250 V / 10,0 A
The length of the supply cord 2 m
Dimensions (V, W, H – approx.) 172 x 244 x 282 mm
Weight 26,5 kg
Warranty 24 months

OT230.200

230 V / 230 V / 20,0 A

Technical parameters

Power voltage 230 V / 50 Hz
Output voltage 230 V
Output current 20,0 A
Output frequency 50 Hz (identical to network frequency)
Output voltage stability by network stability
Stability of the output frequency by network stability
Galvanically separate output YES
Fuse input circuit breaker B 20,0 A
Fuse Output circuit breaker B 20,0 A
The length of the supply cord 2 m
Dimensions (V, W, H – approx.) 280 x 250 x 360 mm
Weight 44,0 kg
Warranty 24 months

In detail

Sine waveform of the output voltage

The output voltage is obtained by transforming the mains voltage 230 V / 50 Hz. The course of the output voltage is clean with a frequency of 50 Hz without parasitic oscillations.

Separation of the output from the mains voltage

A transformer with separation of primary and secondary windings is used to transform the voltage. The output voltage is galvanically separated from the 230 V mains voltage.

Shielded separation of primary and secondary windings

The primary and secondary windings are separated from each other by a grounded shield.

Soft-start

The high power isolating transformers are equipped with a Soft-start function for safe start-up.

Illuminated switch

For easy identification of switching on, the isolation transformer is equipped with an illuminated switch.

Robust metal chassis

The entire device is housed in a robust metal chassis, designed for deployment even in the most demanding operations.

Carrying handle

The isolation transformer is equipped with a handle for easy portability.

Quality finish

The surface finish of the chassis is made with high-quality and durable powder paint.

Documents to download

Manual OT230.200

  • Download

Manual OT230.ostatní

  • Download